                                GSTRAP 4B
产品名称: GSTRAP 4B
英文名称: GSTRAP 4B
产品编号: 28-4017-45
产品价格: 0
产品产地: 美国
品牌商标: GE
更新时间: null
使用范围: null
- 联系人 :
- 地址 : 上海市宝山区友谊路1506号东智广场1109室
- 邮编 : 201900
- 所在区域 : 上海
- 电话 : 138****5983 点击查看
- 传真 : 点击查看
- 邮箱 : 342786402@qq.com
| 28-4017-45 | GSTRAP 4B, 5 X 1 ML | 
| 28-4017-46 | GSTRAP 4B, 100 X 1 ML | 
| 28-4017-47 | GSTRAP 4B, 1 X 5 ML | 
| 28-4017-48 | GSTRAP 4B, 5 X 5 ML | 
| 28-4017-49 | GSTRAP 4B, 100 X 5 ML | 
| 28-4058-44 | HiTrap Capto Adhere 5x1ml | 
| 28-4058-46 | 5x5 ml Hitrap Capto adhere | 
| 28-4082-53 | HITRAP MABSELECT, 5 X 1 ML | 
| 28-4082-55 | HITRAP MABSELECT, 1 X 5 ML | 
| 28-4082-56 | HITRAP MABSELECT, 5 X 5 ML | 
| 28-4082-58 | HITRAP MABSELECT XTRA, 5X1ML | 
| 28-4082-60 | HITRAP MABSELECT XTRA, 1X5ML | 
| 28-4082-61 | HITRAP MABSELECT XTRA, 5X5ML | 
| 28-4110-01 | HiTrap Butyl HP, 5x1ml | 
| 28-4110-05 | HiTrap Butyl HP, 5 x 5ml | 
| 28-4110-07 | HiTrap HIC Selection Kit, 7x1 | 
| 28-9075-46 | StrepTrap HP 5 x 1mL | 
| 28-9075-47 | StrepTrap HP 1 x 5mL | 
| 28-9075-48 | StrepTrap HP 5 x 5mL | 
| 28-9165-37 | HiTrap Capto DEAE, 5X1ML | 
| 28-9165-40 | HiTrap Capto DEAE, 5X5ML | 
| 28-9187-78 | MBPTrap 5 x 1mL | 
| 28-9187-79 | MBPTrap 1 x 5 mL | 
| 28-9187-80 | MBPTrap 5 x 5mL | 
| 28-9343-88 | HiTrap Capto IEX Selection Kit | 
| 28-9520-85 | HiTrap Con A 4B 5 x 1 ml | 
| 28-9520-96 | HiTrap Con A 4B 5 x 5 ml | 
Glutathione Sepharose™ 4B Media/GSTrap 4B Columns - Easy Purification
- Fast and simple purification of GST*-tagged proteins.
- GSTrap™ 4B 1-ml and 5-ml columns are prepacked with Glutathione Sepharose™ 4B.
- GSTrap™ 4B are designed to be used with a syringe, pump, or chromatography system, such as ÄKTAdesign
Glutathione Sepharose™ 4B Media/GSTrap 4B Columns - Easy Purification
Technical Information
 
 
GSTrap 4B 1-ml and 5-ml columns are prepacked with Glutathione Sepharose 4B for fast purification of GST-tagged proteins and scale-up.
GSTrap™ 4B columns are used for the purification of GST-tagged proteins from bacterial lysates and other glutathione S-tranferases or glutathione-dependent proteins. Mild elution conditions preserve protein antigenicity and function.
For an introduction to Glutathione S-transferase (GST) Gene Fusion System, see Introduction to Glutathione S-Transferase (GST) Gene Fusion System.
| Columns: | Capture   GSTrap 4B 1 ml Polishing HiLoad 16/60 Superdex 200 pg | 
| Sample: | Cell extract from E. coli expressing GST-hippocalcin (Mr 45 000) after lysis with CelLytic Express | 
| AC binding/wash buffer: | 10 mM sodium phosphate, 140 mM, pH 7.4 | 
| AC elution buffer: | 50 mM Tris-HCl, 10 mM reduced glutathione, pH 8.0 | 
| GF buffer: | 50 mM phosphate buffer, 150 mM NaCl, pH 7.2 | 
| System: | ÄKTAprime plus | 
 
 
 
 
1 Low molecular weight markers
2 Start material (diluted 1:20)
3 Eluted pool GSTrap 4B
4 Eluted pool GSTrap 4B (diluted 1:50)
5 Peak 1, HiLoad 16/60 Superdex 200 pg
6 Peak 2, HiLoad 16/60 Superdex 200 pg
| TECHNICAL SPECIFICATIONS | |
| Ligand | Glutathione | 
| Ligand coupling method | Epoxy activation | 
| Dynamic binding capacity* | > 5 mg horse liver GST/ml medium | 
| Matrix | Agarose, 4% | 
| Average particle size | 90 μm | 
| pH stability | 4-13 | 
| Storage | 20% ethanol | 
| Storage temperature | 4°C to 30°C | 
| HiTrap prepacked columns | |
| Column volume | 1 ml and 5 ml | 
| Column dimensions | 0.7 × 2.5 cm (1 ml); 1.6 × 2.5 cm (5 ml) | 
| Recommended flow rate† | 0.2-1 ml/min (1 ml); 0.5-5 ml/min (5 ml) | 
| Max. pressure† | 3 bar (0.3 MPa) | 
| * Binding of GST to glutathione is flow-rate dependent and lower flow rates often iincrease the binding capacity. This is an important consideration, especially during sample loading and elution. † H2O at 25°C. 
 | |
http://www.gelifesciences.com/aptrix/upp01077.nsf/Content/Products?OpenDocument&moduleid=38863